Standby generators for a Louisiana home

Short answer

A standby generator is a permanently installed unit that starts on its own when utility power fails. In Louisiana it runs on natural gas or propane, sits on a pad above flood elevation, feeds an automatic transfer switch and carries the circuits that switch controls.

By Jazzy Construction · LSLBC Residential Construction License #8725 · Published November 19, 2026 · 8 min read

Service page: Solar, battery and generator backup power

What a standby generator is, and what it is not

A standby generator is bolted down. It sits on a pad beside the house, wired into the electrical service through an automatic transfer switch, and connected to a fuel line. When the utility drops, it starts within seconds and the house keeps running without anyone touching it. When the utility returns, it shuts itself down.

That is different from the portable generator in the shed. A portable unit has to be rolled out, filled, started and plugged in, and it has to be kept far enough from the house that the exhaust does not enter a window. It is a useful tool for a short outage and a poor plan for a week of August heat.

A standby generator is also not the same thing as a battery. A battery takes over instantly and silently and runs out of stored energy. A standby generator takes a few seconds to start and runs as long as fuel reaches it. The two are complementary, which is why a home microgrid often uses both. The battery backup page covers the other half.

Natural gas or propane for a standby generator

Natural gas is the easier fuel when the house already has a gas meter. The line never needs filling, so a standby generator on a gas main can run for as long as the utility maintains pressure, and in most of the New Orleans metro the gas distribution system stays pressurized through a storm. The trade is that a gas generator is only as reliable as the gas utility, and a storm that damages the distribution system takes both services down.

Propane is the choice where there is no gas main. It needs a tank sized for the outage you are planning for, and the tank needs to be filled before a storm rather than during one. A 500 gallon tank holds more than most households expect and less than a long outage can consume, so the arithmetic matters. The hurricane backup power guide walks through the fuel math.

Diesel exists at this scale too, mostly on larger units and on properties far from a gas supply. It stores for a limited time, needs treatment, and needs a delivery plan. For a house in the metro, the two mainstream choices are gas and propane.

Sizing a standby generator from the load list

A standby generator is sized from what the house draws, not from its square footage. The method is the same one an electrician uses for a service calculation: add the running watts of every load you want on backup, then add the starting surge for the largest motor on the list.

Central air drives the number more often than anything else. A compressor can draw several times its running current in the second it starts, and a generator that carries the steady state but not the surge will trip on the first hot afternoon. A soft start kit on the unit lowers that surge and can bring a house into a smaller generator, which is worth discussing before the unit is ordered rather than after.

A well pump is the second item that surprises people. A 240 volt pump motor has a hard start, and in a rural parish it is often the load that decides the size of the standby generator. The rest of the list, the refrigerator, the freezer, some lights, fans, the router and a window unit, adds up far more slowly than those two motors.

There are two ways to cover a big load list. One is a generator large enough for everything at once. The other is a managed system that sheds circuits, keeping the air conditioning off while the well pump runs and bringing it back when the compressor stops. Managed systems cost less for the same coverage of the loads that matter, and they need an owner who understands what will and will not run at the same time.

The transfer switch a standby generator needs

A standby generator is only safe when it is behind an automatic transfer switch. The switch disconnects the house from the utility before the generator is connected, so power cannot travel backward up the service drop onto lines where a crew is working. The National Electrical Code covers these installations in Article 702.

The switch also decides the scope of the backup. A service-entrance rated switch can carry the whole panel, which means any circuit can run, subject to the generator's capacity. A smaller switch fed from a subpanel carries only the circuits moved into that panel. Either is legitimate; the second is cheaper and asks the homeowner to choose the circuits deliberately.

The post on what a transfer switch does covers the device, the difference between a switch and an interlock kit, and the questions to settle before the unit is delivered. An interlock kit on a portable generator is a real option, and it is a different scope with different limits.

Where a standby generator goes on a Louisiana lot

Placement is a code question and a practical one. The unit needs clearances from the house, from windows and doors, and from the property line, and the exhaust has to point away from anything that opens. Manufacturers publish those distances and the inspector checks them.

In Louisiana, elevation matters as much as setback. A standby generator on a slab at grade in a flood zone is a unit that floods, and a flooded unit is a replacement, not a repair. A raised pad above base flood elevation keeps the enclosure and the controls out of standing water, and it is a small cost next to the unit itself.

Sound is the other practical question. A standby generator is audible at the property line, and a bedroom wall eighteen inches from the enclosure is a bad arrangement for a machine that runs at three in the morning. Position and the sound rating of the unit both matter, and both are easier to plan than to fix later.

Permits for a standby generator

A standby generator installation needs an electrical permit, and in most jurisdictions a fuel connection review as well. Placement and clearances are inspected, and the transfer switch has to be visible and labeled.

In the City of New Orleans, the electrical work falls under the same licensing rule that governs solar: a Class A Master Electrical Contractor licence from the City is required for the electrical scope. Jefferson Parish and the surrounding parishes run their own permit offices with their own requirements, and a licence from one does not cover the other. The New Orleans building permits guide describes the general sequence.

Jazzy Construction holds LSLBC Residential Construction License #8725 and works statewide. The electrical scope on a standby generator is performed by a licensed Class A master electrical contractor. We run the survey, the pad, the permit coordination, the gas line trenching where it applies, the inspection and the warranty around that electrical scope.

Upkeep a standby generator actually needs

A standby generator that has not run since it was installed is a question mark, not an asset. Most units exercise themselves weekly on a schedule set at commissioning, and that schedule is worth leaving alone. The exercise cycle is how the owner learns that the battery is flat or the fuel solenoid has stuck, at a convenient moment rather than during a storm.

Beyond the exercise cycle, the work is routine: oil and filter, spark plugs on a gas unit, an air filter, and a battery every few years. Propane units need the tank level checked before hurricane season, and a tank that has sat below half from May to November is a planning failure.

It is also worth running the house on the standby generator once a year with the utility disconnected, so the transfer switch is proven under load rather than assumed. A switch that has never transferred is a switch nobody has tested.

When a standby generator is the right call

A standby generator is the right answer when the outage is long and the load list is heavy: central air, a well pump, a shop, medical equipment, a house full of people who are not leaving. It is also the right answer when the house already has natural gas, because the fuel problem solves itself.

It is the wrong answer when the outage is short, the budget is tight and the loads are light. A battery covers a few hours of refrigerator and lights quietly and needs no fuel at all, and for a household that mostly wants the router and the fans to stay on, that is enough.

For most Louisiana houses the honest answer is a mix, and the green energy overview explains how the parts fit. If you want the question answered for your address, send a quote request with a photo of the electrical panel and a note on what you want running in an outage. Our solar, battery and generator backup power page covers the combined scope, and the home microgrid page covers the system as a whole.

Common questions

How big a standby generator does a Louisiana house need?
It depends on the load list, and central air usually decides it. Add the running watts of everything you want on backup, then add the starting surge of the largest motor. A soft start kit on the air conditioner can lower that surge enough to move a house to a smaller generator.
Will a standby generator run central air?
A properly sized one will. The compressor's starting surge is the constraint, not its running load, so the unit has to be chosen for the surge or fitted with a soft start kit. A managed system that sheds the air conditioning while a well pump runs covers more load with a smaller generator.
Is natural gas or propane better for a standby generator?
Natural gas is simpler where a meter already exists, because the line never needs filling and usually stays pressurized through a storm. Propane is the choice without a gas main, and it needs a tank sized for the outage you are planning for and filled before the season.
Does a standby generator need a permit in New Orleans?
Yes. The installation needs an electrical permit and a review of the fuel connection, and placement and clearances are inspected. The electrical scope requires a Class A Master Electrical Contractor licence from the City, and a historic district can add a Certificate of Appropriateness.
How long will a standby generator run during an outage?
As long as fuel reaches it. On natural gas that means as long as the utility maintains pressure. On propane it means as long as the tank lasts, which is why the tank size and the fill date are part of the design rather than an afterthought.
What maintenance does a standby generator need?
It exercises itself weekly on a schedule set at commissioning, and that cycle should be left alone. Beyond it, the routine work is oil and filter changes, plugs on a gas unit, an air filter and a battery every few years. Once a year the house should be run on the generator with the utility disconnected, to prove the transfer switch under load.